RTK Base Station Setup
DK01672,0000139 -19-22JUL11-2/2
450 MHz Amplier Specications (USA
and Canada only)
Model Number PF81443
Frequency Range 450-470 MHz
Input Power 0-2 W
Output Power
0-50 W
Current During Transmission
8 amp
Nominal Voltage
13.8 V DC
Internal fuse
15 amp
In/Out Impedance
50 ohm
Operating Voltage 11-15 V DC
Max Duty Cycle 100%
Operating Temperature -30 to 60° C
In RF Connector Female TNC
Out RF Connectors
Female N-Type
Power Connector Amphenol (EcoMate C016
20D003 110 12)
There are 3 connections located at the bottom of the
power amplier:
1. 12 VDC power input
2. RF input via TNC connector
3. RF output via N-Type connector
The connectors should only be nger-tight. Using tools can
over tighten and damage the RF and power connectors.
A 13.8 V power supply capable of providing a constant
10 amp to the amplier is required. Amplier operation
with insufcient voltage can lead to higher amplier
operating temperatures. Insufcient current can cause the
amplier to not amplify or only partially amplify the RF
signal. These conditions result in incomplete or no RTK
transmissions being received by the vehicle.
IMPORTANT: Make sure the antenna and coax
are attached before the amplier module is
powered ON or damage to the amplier could
PUPC000028 —UN—06DEC09
Amplier Connection Ports
occur. Do not remove the coax or antenna
while the amplier is powered ON. Avoid
water intrusion by keeping the connections
attached whenever possible.
Make sure the power connector is attached
and unpowered when handling the RF IN and
RF OUT connectors. The ground provided by
the power connector protects the amplier
against possible electrostatic discharge.